google eraction of smoke tube boiler com
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Shell and tube boilers are also referred to as fire tube or smoke tube boilers. Fire tube boilers; contain long steel tubes through which the hot gasses from a furnace pass and around which the water to be converted to steam circulates. Fire tube boilers, typically have a lower initial cost, are more fuel efficient and easier to operate.Get Price
15,352. Pielock, E. July 1. Smoke, consuming; air supply, heating. - In boilers comprising a firebox a and a tubular boiler b separated by a combustion chamber c, air is admitted at k, and is heated in the coiled pipe i before issuing through slots l to complete the combustion of the gases which pass from the fire - box by the pipe g. Air to be supplied under the grate h enters above the Get Price
The water-tube boiler went through several stages of development. Straight-Tube Boiler: The 1st water-tube boiler was the straight-tube boiler, in which straight tubes, 3 to 4 in OD, inclined at about 15 and staggered with 7 to 8 in spacing, connected two vertical headers.Get Price
Aug 01, 2008 · The overview and a schematic diagram of the commercial-scale indirect plasma and chemical hybrid system are shown in Fig. 1, Fig. 2, respectively.The flue gas is generated by the steam generation boiler (Takao Iron Works Co., Ltd.) of 2.0 t/h capacity, which fires a city gas (13 A) at a rated value of 121 Nm 3 /h. Subsequently, in order to protect the polypropylene …Get Price
For water tube boiler (Z boiler): 1. Stop the firing – open up the combustion chamber, – Fill up the boiler water level to full. – leakage can seen easily be seen & identify the individually boiler water tube. For smoke tube boiler: – Stop the firing – open the smoke side drain valve, – If there is any leakage water will come out.Get Price
Jul 29, 2016 · h) Identify measurement locations and verify access. i) The most common flue gas measurement location is immediately downstream of the steam generation section of a water-tube type boiler. For a fire-tube type boiler the flue gas sample is most commonly taken as the exhaust gases exit the boiler proper. Establish tune-up timeframe. 39.Get Price
Jan 17, 2015 · CLASSIFICATION OF STEAM BOILERS • Though there are many classifications of steam boilers, yet the following are important. ACCORDING TO THE CONTENTS IN THE TUBE: a) fire tube or smoke tube boiler b) water tube boiler. 10. FIRE – …Get Price
May 19, 2016 · Indications of a tube failure were present 1 hours or more before the apparent fire. The subsequent symptoms of fire were caused by overheating of the port side boiler casings by intense radiant heat from the furnace, after a collapse of the refractory behind the water-wall on the port side of the furnace.Get Price
Dec 15, 2011 · The complete compound loco emerged in 1929, and was constantly experimented with until rebuilt in 1937, emerging as a conventional Doncaster 3 cylinder simple with a fire tube boiler. The water tube boiler was not scrapped, went to Darlington and was used until 1966 for plant steam supply.Get Price